MULTI M-800P DC in AC Clamp Tester

Specialized Clamp Tester for Detecting DC Current Components in AC Circuits

The MULTI M-800P DC in AC Clamp Tester is a specialized measuring instrument designed to detect and measure small DC current components present in AC circuits. In addition to conventional AC and DC current measurement, the M-800P provides a dedicated function for displaying the percentage of DC current contained in an AC current circuit.

This capability addresses an important measurement requirement in applications such as photovoltaic (PV) power generation systems and solar inverters, where DC current components may be present in the AC output. Excessive DC injection into an AC system can be an important issue to investigate during inverter inspection and maintenance. The M-800P helps technicians check the DC component in an AC conductor and compare the measured result with the applicable requirements.

How Does the DC in AC Measurement Work?

Unlike a conventional clamp meter that displays only the measured AC or DC current, the M-800P includes a dedicated DC percentage measurement function.

According to the manufacturer's instruction manual, the instrument calculates the percentage using the following relationship:

DC Current Percentage (%) = (DC Current ÷ AC Current) × 100

After performing the required zero adjustment, the operator selects the DC percentage function and clamps the instrument around a single insulated conductor carrying AC current. The instrument then displays the calculated DC component as a percentage of the AC current.

This allows the technician to assess the DC component in the AC circuit without relying only on a separate AC current reading and a separate DC current reading.

Designed for Solar Inverter Inspection

One of the key applications identified by MULTI is DC offset surveillance in actual field installations, including solar inverters. The instrument helps technicians investigate whether the DC current component in an AC circuit is below 1% of the rated AC current, as referenced by the manufacturer.

The displayed percentage provides a practical measurement reference for inspection and maintenance. The applicable regulatory limit and the method of determining rated AC current must still be verified against the relevant standard and installation requirements.

Measurement Functions

The M-800P combines five measurement functions in one portable instrument:

  • ACA – AC Current: Measures AC current up to 150 A.

  • DCA – DC Current: Measures DC current up to 150 A.

  • DC in AC (%): Detects the DC current component in an AC circuit and displays its percentage.

  • ACV – AC Voltage: Measures AC voltage up to 600 V.

  • DCV – DC Voltage: Measures DC voltage up to 600 V.

Both AC and DC current measurements use two automatically selected ranges: 15 A and 150 A. Voltage measurement also provides automatic selection between 150 V and 600 V ranges.

Measurement Accuracy and Practical Operation

The M-800P uses a clamp-type current transformer with a 23 mm internal diameter. Its AC current detection method is specified as True RMS using an analog arithmetic method. For DC current measurement, the instrument provides a dedicated zero-adjustment function to compensate for zero-point changes that may result from magnetization or the Earth's magnetic field.

Additional functions include Data Hold, automatic power-off after approximately 10 minutes and a rotary range selector. These features support practical field measurements and routine inspection work.

Compact Design for Field Use

With dimensions of approximately 48 × 178 × 24 mm and a weight of approximately 120 g without batteries, the M-800P is designed for portable field use. It operates on three AAA alkaline batteries and is supplied with voltage test leads and a soft carrying case.

Key Applications

  • Solar inverter inspection and maintenance

  • DC component monitoring in AC circuits

  • Investigation of DC offset in AC output circuits

  • AC and DC current measurement

  • AC and DC voltage measurement

  • Electrical inspection and troubleshooting

Important Safety Information

The M-800P is specified for low-voltage circuits. The manufacturer warns against measuring power lines carrying more than 600 V AC and requires the use of insulated conductors. Bare conductors must not be clamped. Follow the instruction manual, verify the circuit voltage before measurement and observe the specified operating procedure, especially the zero-adjustment procedure for DC current and DC percentage measurements.

Extra Information

Brand:
Multi
Product Type:
DC in AC Clamp Tester
Measuring Method:
CT Clamp Method
CT Internal Diameter:
23 mm
AC Current Ranges:
15 A (±1.0% rdg ±5 dgt ) / 150 A ( ±2.0% rdg ±8 dgt )
DC Current Ranges:
15 A (±1.0% rdg ±5 dgt ) / 150 A ( ±2.0% rdg ±8 dgt )