MULTI MIS-3D Digital Insulation Resistance Tester

Multi

No reviews yet Write a Review
SKU:
Multi-MIS-3D
AED0.00
AED0.00

Description

The MULTI MIS-3D is a compact digital insulation resistance tester designed for electrical insulation testing and AC voltage measurement. It provides three insulation test voltages of 250V, 500V and 1000V, with effective measuring ranges up to 50MΩ, 100MΩ and 2000MΩ respectively.

The tester features a large 3.5-digit LCD with bar graph display and backlight, making readings easier to observe in low-light working environments. Data Hold and automatic power-off functions improve convenience during field measurements.

For safer insulation testing, the MIS-3D includes a warning lamp for detecting voltage in the circuit or capacitor and an automatic discharge function for capacitors. Its compact and rugged design makes it suitable for electrical inspection, maintenance and field testing applications.

The instrument complies with IEC 61010-1 safety requirements and EN 61326 EMC requirements. It is supplied with line and earth test leads, batteries, test lead case, belt and instruction manual.

Extra Information

Brand:
Multi
Rated voltage and effective measuring range:
250V-50MΩ,500V-100MΩ,1000V-2000MΩ
Minimum measurable resistance at rated voltage:
0.25MΩ,0.5MΩ,1MΩ
Rated current:
1mA+20%-0%
Open circuit voltage:
Rated voltage+30%-0%
Short circuit current:
Withstanding Voltage:
AC 3700V, 1 minute (Between input terminal and outer case)
Storage Temperature:
-10℃~60℃, 80% RH max (Without condensation)
Operating Temperature:
0℃ to 40℃, 80% RH max. (Without condensation)
Power supply:
1.5V (AM-3, R6 or "AA" size)×6
Weight:
Approx. 330g (Excluding batteries)
Safety standard:
IEC 61010-1 - Installation categoryⅡ, 600V phase to earth.
Size2:
170(W)×105(D)×54(H)mm
Accessories:
Line test lead:1 - Earth test lead:1 - Batteries:6 - Test lead case:1 - Belt:1 - Instruction manual:1
Display:
3.5 digit LCD with bar graph display, max. reading of 3200 count and annunciators
Optional accessory:
Test probe with remote switch
Data hold indication:
"DH" mark on LCD readout
Low battery indication:
Battery mark on LCD readout
E.M.C. standard:
EN 61326
Function:
Insulation resistance, AC voltage
Constructional standard:
In accordance with IEC1557-2 or JIS C1302 (1994)
Overload protection:
120% of the highest nominal output voltage (10 sec.)
Battery check:
DC 6.3V~9.5V
Temperature characteristics(0~40℃):
±5% rdg of specified accuracy
Accuracy(DC 250V):
Measuring range:0~50MΩ~OL(∞) / First effective range:0.05MΩ~20MΩ
Accuracy(DC 500V):
Measuring range:0~100MΩ~OL(∞) / First effective range:0.1MΩ~50MΩ
Accuracy(DC 1000V):
Measuring range:0~2000MΩ~OL(∞) / First effective range:2MΩ~1000MΩ
AC voltage (50/60Hz):
Range/Accuracy/Input impedance/Maximum input voltage AC 600V/±2.5% of full scale/Approx. 20M/AC 600V rms
Response time:
Less than 5 sec. (Auto ranging)
Infinity indication:
"OL" mark on LCD readout (Over 3200 count)